ERX 8.0.x Hardware Guide

Figure 49: E3 and T3 Module LEDs

Functional status LEDs

Interface status LEDs

OK

FAIL

ONLINE

REDUNDANT

0
1
2

RED

ALM

YEL

ALM

SYNC

g013770

LED Activity

When the system boots, it runs a series of tests for each module installed in
the system, and the LEDs display various configurations. See Table 12 and
Table 13 to understand normal and abnormal LED activity.

NOTE: When you reboot the system after installing a new version of the software,
the line modules appear to boot twice.

Table 12: Normal Activity of Functional Status LEDS During Booting

OK

FAIL

ONLINE

Status Process

off

on

(off for GE-2 LM and
GE-HDE LM)

off

1. Module is in the
power-up restart
state; the FAIL LED
stays on briefly.

off

on

off

2.

Module is

initializing, and
diagnostic tests are
running; the FAIL LED
stays on briefly.