Control panel, Chromatherapy lamp – Jacuzzi GQ99000 User Manual

Page 2

Advertising
background image

Jacuzzi

©

Chromatherapy: Installation and Operation

Page 2 of 5

GQ99000 • 07-08

Lens cable (1-4)

Figure 3. Hole for Control Panel

detaiL

1/2 inch

5/32 inch

1-1/16 inch

Figure 4. Hole for Chromatherapy Lamp(s)

1-5/8 inch

Caution: The panel and lamp(s) require modular cables from

behind. Make sure the proposed location of the panel and lamp(s)

will not cause cables to interfere with the bath plumbing
The control panel and each lamp must be mounted on a minimum

flat surface space of the bath shell, see Table 1, Mounting Surface

Requirements.

Table 1. Mounting Surface Requiements

EQUIPMENT

FLAT MOUNTING SURFACE

------------------------------------------------------------------------

Control panel

3 x 2 inches

Lamp (each)

2-1/2 by 2-1/2 inches

Next, consider the following cable lengths, starting with the control

box. See Table 2, Cable Lengths.

Table 2. Cable Lengths

CABLE

LENGTH

--------------------------------------------------------

Control box cable

32 inches

Control panel cable

72 inches (6 feet)

Chromatheraphy lamp 84 inches (7 feet)

The control box must be mounted on a stud beam or secure wall

within 32 inches of the GFCI power outlet. The outlet must be a

minimum of 4 inches above the floor. In addition it must be located

no further than the length that the modular control cable or any

lamp cable may extend.

Once the location of the control box has been determined, you

may determine the location of the control panel and the lamp(s),

and prepare to drill a hole for each item.

Control Panel

Before marking the inside of the bath shell, place masking tape

over the entre area of the proposed hole. The tape will help

prevent chipping of the acrylic.

Writing on the tape, use a pointed marker to indicate the outline of

the hole for the control panel, see Figure 3. The control panel is

2-1/2 by 1-1/2 inches and requires a minimum of 3 by 2 inch flat

mounting surface. Carefully mark the center of the hole.

Also mark the 5/32 inch notch at the right side of the diameter,

and mark the center of the notch. It is critical to measure the hole

and notch precisely.

Chromatherapy Lamp

Use a marker to indicate on the inside of the bath shell where the

lamp(s) will be located

Caution: Before marking the inside of the bath shell, place

masking tape over the entire area of the proposed hole, to help

prevent chipping of the acrylic.

Use a marker to indicate the location of the Chromatheraphy

lamp(s). The lamp is 2 inch diamerter and requires a minimum

of 2-1/2 diameter flat mounting surface. (Locate as many lamps

as are intended for installation.) Indicate a hole for 1-5/8 inch

diameter, see Figure 4.

Advertising