Cv-a1 block diagram, Functions and operations, Basic functions – JAI CV-A1-20 User Manual

Page 7: Cv-a1-20

Advertising
background image

CV-A1-20

5.4. CV-A1 Block Diagram

Fig. 8. Block diagram.

6. Functions and Operations

6.1. Basic functions

Some of the primary camera functions need a general introduction before the operation modes
are described. The list below shows the primary functions from the command list.

SM Shutter Mode

Normal shutter, Programmable Exposure

SH Shutter Speed

Off to 1/140,000 second

PE Programmable Exposure 1.3 H to 1023.3 H

SC Scanning Format

Full frame, 1/2 partial, 1/3, 1/6 partial

BI Binning

Off, vertical, horizontal, vertical + horizontal

TR Trigger Mode

Normal, Edge, PWC, frame delay readout

Long time exposure, start-stop, smearless (Edge)

HC

HD

Accumulation Sync.,

async.

The shutter SM can be set to normal (SM=0), where the exposure time is selected from 16 fixed
step with the command SH, or programmable exposure (SM=1). The command PE allows 1023
step with 1 line period resolution. (83.6 µs). Note that PE=0 and PE=1 results in 1.3H.
The CCD scanning format SC can be selected between full or partial scanning. With partial
scanning, only the vertical central part of the CCD sensor is read out with a higher frame rate.
The partial scan is done by a fast dump read out of the lines in the vertical ccd register down to
the top of the partial image. The partial part of the image is read out with normal speed. The
lines below the partial image are read out and dumped with a high speed.
Some signal distortion can be expected below highlighted areas, (saturated areas). It is caused

by limitation in the vertical ccd register transfer efficiency at high speed.

Imaged scene

Partial scanning.

Aspect ratio correct

1380 pixels

1/2 PS, 51

3 pixels

1/6 PS, 171 pixe

ls

1/3 PS, 341 pix

els







Fig. 9. Partial scanning.

- 6 -

Advertising