English, Corner baths, Specifications – Jacuzzi HE96000 User Manual

Page 20: Comfort plus whirlpool bath page 20, Installation and operation, Tara ™ plus left hand motor, Tara™ plus right-hand back motor

Advertising
background image

Comfort PLUS Whirlpool Bath

Page 20

www.jacuzzi.com

Installation and Operation

English

*Add ¼" (6mm) to this dimension when roughing-in for 3-wall niche.

Corner Baths

MODEL

PRODUCT

WEIGHT

OPERATING

GALLONAGE

TOTAL WEIGHT/

FLOOR LOADING

DIMENSIONS

DRAIN/OVERFLOW

DIMENSIONS

SKIRT &

MOUNTING

CUTOUT

HEATER

60"

(1524 mm) L

60"

(1524 mm) L

20-¾" ( 527 mm) H

984 lb

(447 kg)/

39 lb/ft

2

(190 kg/m

2

)

74 U.S. gal

(280 liters)

118 lb

(54 kg)

TARA™ PLUS

LH, RH, LBM, RBM

16" (406 mm) A

12-⅜" (314 mm) B

Optional

See

Pages

12-13

Factory Installed

(S750000 HEATER KIT)

60"

(1524 mm) L

60"

(1524 mm) L

20-½" ( 521 mm) H

1177 lb

(535 kg)/

47.1 lb/ft

2

(229 kg/m

2

)

Min 55 U.S. gal

(208 liters)

Max 90 U.S. gal

(341 liters)

130 lb

(59 kg)

CAPELLA™ PLUS

LH, RH

18" (406 mm) A

12-⅛" (314 mm) B

Optional

See

Page 12

Factory Installed

(S750000 HEATER KIT)

60"

(1524 mm) L

60"

(1524 mm) L

20-½" ( 521 mm) H

1038 lb

(472 kg)/

41.5 lb/ft

2

(202 kg/m

2

)

Min 55 U.S. gal

(208 liters)

Max 90 U.S. gal

(341 liters)

140 lb

(64 kg)

CAPELLA™ PLUS

WITH INTEGRAL

SKIRT

RFM

18" (406 mm) A

12-⅛" (314 mm) B

Integral

NA

Factory Installed

(S750000 HEATER KIT)

60"

(1524 mm) L

60"

(1524 mm) L

20-¾" ( 527 mm) H

1160 lb

(527 kg)/

46.4 lb/ft

2

(226 kg/m

2

)

Min 61 U.S. gal

(231 liters)

Max 87 U.S. gal

(329 liters)

135 lb

(61 kg)

TARA™ PLUS WITH

INTEGRAL SKIRT

RH

16" (406 mm) A

12-⅜" (314 mm) B

Integral

NA

Factory Installed

(S750000 HEATER KIT)

DRAIN/OVERFLOW

A

B

SPECIFICATIONS

(Corner) LH=Left Hand MTR, RH=Right Hand MTR, LBM=Left Back MTR, RFM=Right Front MTR,

RBM=Right Back MTR

H

SIDE VIEW

END VIEW

2”

CAPELLA

™ PLUS LEFT HAND MOTOR

(50,8 mm)

(Suction Heater)

(Motor)

TARA™ PLUS Left-Hand BACK MOTOR

L

H

SIDE VIEW

END VIEW

2”

(51 mm)

(Motor)

(Suction Heater)

L

H

SIDE VIEW

END VIEW

2”

TARA

™ PLUS LEFT HAND MOTOR

(51 mm)

(Suction Heater)

(Motor)

CAPELLA 60 WITH INTEGRAL SKIRT

1"

(25 mm)

H

FRONT VIEW

SIDE VIEW

TARA™ PLUS Right-hand BACK MOTOR

L

H

SIDE VIEW

END VIEW

2”

(51 mm)

(Motor)

(Suction Heater)

H

SIDE VIEW

END VIEW

1”

TARA

™ PLUS with Skirt RIGHT HAND MOTOR

(25,4 mm)

(Suction Heater)

(Motor)

The overall dimensions are nominal with a tolerance of +0 and -¼˝ (6mm).

FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.

RapidHeat

TM

: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.

Motor/Pump: 120 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.

Advertising