Warning – Jenn-Air PROSTYLE JGD8348CDP User Manual

Page 8

Advertising
background image

8

TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS

Propane Gas conversion is to be performed by
a Jenn-Air Authorized Service Contractor (or
other qualified agency) in accordance with the
manufacturer’s instructions and all codes and
requirements

of

the

authority

having

jurisdiction. Failure to follow instructions could
result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for this conversion.

WARNING

ELECTRICAL POWER AND GAS MUST BE

TURNED OFF PRIOR TO CONVERSION

WARNING

Natural Gas To Propane Gas (LP) Conversion Instructions

Models - JGD8348CDP

Manifold - Propane Gas pressure required - 10

²

W.C.

Incoming Propane Gas pressure required to appliance
pressure regulator - 11

²

- 12

²

W.C.

Propane Conversion Orifice Hoods are supplied with this
model.

Propane Gas input specified - 46,000 BTU/hr.

JGD8348CDP

INCHES

BURNER

BTU/hr

ORIFICE

DIAMETER

COLOR

Left Rear (LR)

7500

#66

.033

Zinc

Left Front (LF)

7500

#66

.033

Zinc

Center Rear (CR)

6500

#68

.031

Red

Center Front (CF)

9000

#63

.037

Blue

Right Rear (RR)

6500

#68

.031

Red

Right Front (RF)

9000

#63

.037

Blue

Advertising