Assembling the housing, Mounting the housing to the wall – JVC WB-1540 User Manual

Page 13

Advertising
background image

13

1.

Mount the desiccant

Use a tape to adhere the supplied desiccant to the interior
of the lower housing.

2.

Mount the lower housing

Mount the lower housing that is dismantled in Step 2.
(A pg. 10) to the main housing unit using the 3 Screw A
(M4 x 6).
Do so by aligning the position marks of the lower housing
and the main housing unit.

3.

Mount the gasket and gasket gland

Mount the gasket and gasket gland that are dismantled in
Step 1. (A pg. 10) of the housing disassembly procedure
to the lower housing using the 8 Screws B (M4).

1.

Drill a hole into the wall.

Drill a hole (R 45 mm) for inserting the connection cable.
(Refer to left fig.)

2.

Affix anchor bolts onto the wall.

• Affix 4 anchor bolts (M8, 35 mm and above) for attaching

the housing. (Refer to left fig.)

• Affix an anchor bolt for attaching the safety wire, in the

middle (about 60 mm from both ends) of the 2 upper
anchor bolts, 30 mm from the top. (Refer to left fig.)

3.

Mount the safety wire and arm to the wall.

• Mount the safety wire attached to the housing, to the

anchor bolts using the nut and wire.

• Use the nut and wire to mount the housing onto the wall.

Assembling the Housing

3.

2.

1.

Main Housing Unit

Screw A (M4 x 6) x 3

Lower Housing

Gasket

Screw B (M4) x 8

Safety Wire

Gasket Gland

Desiccant

Position Mark

CAUTION:
● Fogging may occur when there are drastic temperature

changes. In this case, continue using without turning off
the power.

● Pay attention when handling the desiccant in order to

maintain its effectiveness.
• Do not remove it from the bag until you are about to use

it.

• Do not wet it or touch it with wet hands.
• Assemble promptly upon adhering the desiccant.
• Be sure to replace the desiccant during maintenance.

CAUTION:
● During assembly, ensure that wires and cables are not

caught in the housing.

● Do not exert force unnecessarily on the gasket or twist it

during mounting.

● Check to ensure that the gasket is in close contact with the

camera.

Mounting the Housing to the wall

202

176

60

152
126

63

45

12

30

1. 2.

Nut

Washer

Safety Wire

Installation Position

Anchor Bolt
(M8, 35 mm and above)

Advertising