0 trouble shooting chart, Trouble shooting chart – Johnson Controls TopClean AS User Manual

Page 29

Advertising
background image

27

IM-AS/02.00 GB (0412)

14.0 Trouble shooting chart

The pump does not prime

•

Air has entered the suction piping; check the seals on the fittings and tighten them
sufficiently.

•

Suction pipe not submerged in liquid.

•

Clearances between impeller/cover and impeller/body have increased. Check and
correct.

•

No liquid in the pump. Introduce liquid.

•

Reduce loss of suction head; reduce the suction height.

•

Formation of air pockets; eliminate and if necessary fit a valve on discharge.

No flow

•

Pump not primed; (see point 8 and previous point).

•

Pump turning in wrong direction.

•

Suction port obstructed.

•

On-off valves closed.

Insufficient flow

•

Increased system back pressure on discharge side; increase piping diameter.

•

Air entering mechanical seal; check its condition.

•

Viscosity of fluid greater than that specified in the order. Contact manufacturer.

•

Clearances between impeller/cover and impeller/body have increased. Check and
correct.

Loss of head

•

Back pressure on discharge side has fallen; throttle the suction pipe.

•

Clearances between impeller/cover and impeller/body have increased. Check and
correct.

Increase in absorbed power

•

Flow rate is lower than required.

•

Pump is turning at higher speed.

•

The impeller does not turn freely. Check it.

•

Viscosity and/or specific weight are higher than stated.

•

Bearings are not in good condition.

Increase in absorbed current

•

The power required has increased (see previous point).

•

Main voltage value has fallen.

•

There is a fault in the electrical system.