IMPORTANT: Review and understand the warnings in

the Safety Information section. They are needed to safely

operate this space heater. Follow all local ordinances and

codes when using this space heater.

WARNING: TEST ALL GAS PIPING AND

CONNECTIONS FOR LEAKS AFTER

INSTALLING OR SERVICING. NEVER

USE AN OPEN FLAME TO CHECK FOR

A LEAK. APPLY A MIXTURE OF LIQUID

SOAP AND WATER TO ALL JOINTS.

BUBBLES FORMING SHOW A LEAK.

CORRECT ALL LEAKS AT ONCE.

1. Provide Propane / L.P. supply system (see Propane / L.P.

Supply section).

2. Connect POL fitting on hose / regulator assembly to

Propane / L.P. tank(s). Turn POL fitting counterclockwise

into threads on tank. Tighten firmly using wrench.

IMPORTANT: Tighten regulator with black adjustment

knob pointing down. Pointing adjustment knob down

protects regulator from weather damage.

3. Connect hose to inlet connector. Tighten firmly using a

wrench. (Fig. 2)

IMPORTANT: Extra hose or piping may be used if needed.

Install extra hose or piping between hose/regulator

assembly and Propane / L.P. tank. You must use the

regulator supplied with heater.

4. Open propane supply valve on Propane / L.P. tank(s)

slowly.

Note: If not opened slowly, excess-flow check valve on

Propane / L.P. tank will stop gas flow. If this happens,

you may hear a click inside the regulator assembly. To

reset the excess flow check valve, close Propane / L.P.

supply valve and open again slowly.

5. Adjust regulator between 7 and 20 PSIG.
Note: Higher regulator setting will allow heater to produce

more heat.

6. Check all connections for leaks.
7. Close Propane / L.P. supply valve.

WARNING: DO NOT ADJUST REGULATOR

BELOW 7 PSIG OR ABOVE 20 PSIG.

HEATER MAY NOT RUN PROPERLY.

Propane/LP

Tank

Supply

Valve

Hose

POL Fitting

Regulator

Adjustment Knob

(pointing down)

(Fig. 1)

Hose

Inlet Connector

(Fig. 2)