Jura Capresso S95 User Manual

Page 21

Advertising
background image

21

Cause

Action

CLEAN UNIT

You have drawn off coffee 220 times or run

Clean as described in chapter 14

the rinsing program 180 times
Message still displayed, although machine

Run cleaning program again; this time do not

cleaned

add cleaning tablet

UNIT CALCED

The espresso/coffee machine sector needs

Run decalcifying program as described in

decalcifying

chapter 15

Message still displayed, although machine

Run cleaning program again; this time using water

decalcified

only and without decalcifying agent

FAULT 2

Temperature too low

– Switch device off
– Leave device for approx. 2 hours at room

temperature

– Switch device on

FAULT 8

Initialisation problem

Switch device off, disconnect from mains,
switch on

20. Problems

Problem

Cause Action

Coffee only flows in dribs

– Powder too fine

– Adjust grinder to a coarser grinding

and drabs while drawing off

– Run the rinsing programme once or twice.

If the problem persists, run cleaning programme

Coffee flow is stopped

– Not enough coffee powder in the system

– Draw off one cup of coffee

after pre-brewing

Grinder is extremely noisy

– Foreign element in grinder

– Proceed as described in chapter 13.5

E

Advertising
This manual is related to the following products:

S90, S9, 601