16

Pump Rotor

(Procedure if rotor is binding)

1. Remove upper shell (see

page 10).

2. Remove filter end cover

screws using 5/16" nut-
driver.

3. Remove filter end cover

and air filters.

4. Remove pump plate

screws using 5/16" nut-
driver.

5. Remove pump plate.
6. Remove rotor, insert, and

blades.

7. Check for debris in pump.

If debris is found, blow
out with compressed air.

8. Install insert and rotor.
9. Check gap on rotor.

Adjust to .003"/.004"
(.076/.101mm) if needed
(see Figure 19).

Note:

Rotate rotor one

full turn to insure the gap is
.003"/.004" (.076/.101mm) at
tightest position. Adjust if
needed.

10. Install blades, pump plate,

air filters, and filter end
cover.

11. Replace fan guard and

upper shell.

12. Adjust pump pressure (see

page 13).

Note:

If rotor is still binding,

proceed as follows.

13. Perform steps 1 thru 6

above.

14. Place fine grade sandpaper

(600 grit) on flat surface.
Sand rotor lightly in
“figure 8” motion four
times (see Figure 20).

15. Reinstall insert and rotor.
16. Perform steps 10 thru 12

above.

150 ROTOR

PFA/P 059

Blade

Sandpaper

Figure 20 - Sanding Rotor

.003"/.004"
(.076/.101mm) Gap
Measured With
Feeler Gauge

Rotor

Gap Adjusting
Screw

Figure 19 - Gap Adjusting
Screw Locations

Fan Guard
(100,000 BTU/Hr
Model Shown)

Filter End Cover

Air Intake Filter

Pump Plate

Air Output Filter

Insert

Rotor

Figure 18 - Rotor Location

Gap Adjusting Screw

Blade

Advertising