26

Item

Measuring

instrument

Test point

Ad justment part

Description

7.SECAM
BL ADJUST

[Method of adjustment using measuring instrument]

Ad justment
of SECAM
BL ACK
OFFSET

Remote
control unit

Signal
generator

1. Input a SECAM full field c olour bar signal.
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 7. SECAM BL ADJUST with ▼/▲MENU key.
5. Set the initial setting value with the – or + MENU key.
6. Switch the ①key (c olour OFF) and ②key (c olour ON) on the

remote control and make sure that there is no colour on the
blac k and white screen.

7. If the black and white s creen is not bes t with the initial setting

value, make fine adjustment until you get the best black and
white screen.

8. While watching the screen, adjust the value to be the same

colour between ON & OFF by ten key on the remote c ontrol
unit.

9. Press the DISPLAY key twice to return to the normal screen.