Johnson Controls ALL RESIDENTIAL MULTI-POSITION 356486-UUM-H-0609 User Manual

Page 2

Advertising
background image

356486-UUM-H-0609

2

Johnson Controls Unitary Products

SECTION II: INSTRUCTIONS FOR

EXAMINING THE FURNACE

INSTALLATION

It is the owner’s responsibility to ensure that an annual inspection of the
entire heating portion of the unit is made by a qualified service agency.
Examine the furnace as outlined below in steps “1 - 8” before each
heating season. Use Figures 1 - 6 for visual reference.

FIRE OR EXPLOSION HAZARD

This furnace is designed and approved for use with Natural Gas
and (LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL
OR SOLID FUEL IN THIS FURNACE.

Burning any unapproved fuel will result in damage to the furnace
heat exchanger, which could result in Fire, Personal Injury, and/or
Property Damage.

FIGURE 1: Component Location - 80% Single & Two Stage Models

FIGURE 2: Component Location - 95% Single & 96% Two Stage Models

Vent Pipe

Pressure
Switch

Silicone
Tube

Rollout
Safety Switch

Gas Valve

Flame
Sensor

Induced Draft
Assembly

Induced
Draft Motor

Limit
Switch

Ignitor

Manifold Pipe

Safety
Door
Switch

Control Board

Flue Collar

Electrical
Junction
Box

Blower

Transformer

Capacitor

(Not used on all models)

Power Factor
Choke

(Not used on
all models)

Vent Pipe

Pressure Switch

Manifold
Pipe

Rollout Safety Switch

Gas Valve

Flame Sensor

Manifold Draft
Assembly

Limit Switch

Ignitor

Safety
Door
Switch

Control Board

Electrical
Junction
Box

Blower

Transformer

Capacitor

Condensate Pan

Silicone
Tube

(Not used on all models)

Power Factor
Choke

(Not used on
all models)

FIGURE 3: Component Location - 80% Modulating PSC Models

FIGURE 4: Component Location - 80% Modulating ECM Models

Pressure
Sensor

Silicone
Tube

Rollout
Safety Switch

Gas Valve

Flame
Sensor

Induced Draft
Assembly

Induced
Draft Motor

Limit Switch

Ignitor

Manifold
Pipe

Safety
Door Switch

Control
Board

Flue
Collar

Electrical
Junction Box

Blower

Transformer

Capacitor

PSC MOTOR

Pressure
Switch

Pressure
Switch

Pressure
Sensor

Silicone
Tube

Rollout
Safety Switch

Gas Valve

Flame
Sensor

Induced Draft
Assembly

Induced
Draft Motor

Limit Switch

Ignitor

Manifold
Pipe

Safety
Door Switch

Control
Board

Flue
Collar

Electrical
Junction Box

Blower

Transformer

Power Factor
Choke

ECM MOTOR

(Not used on
all models)

Advertising