Operator’s Manual

MAINTENANCE

Keep all air vents clear.

Keep the generator clean. DO NOT spray with water.

Periodically check all fasteners and tighten, see the periodic maintenance chart.

GFCI TEST RECORDS:

As with any other safety devices, the GFCIs supplied with these generators must be checked every month to insure that

they are functioning properly. To test the GFCIs, follow the instructions and then enter the date of the test below.

1. With the generator running and the idle control switch in the “START” position, push the “TEST” button. The

“RESET” button should pop out. This should result in the power being off at both outlets of the duplex receptacle.

Verify this by plugging a test lamp into each outlet.

WARNING: IF THE RESET BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLE(S). SEE

AUTHORIZED John Deere CUSTOMER SERVICE REPRESENTATIVE FOR SERVICE IMMEDIATELY.

2. If the GFCI test correctly, restore power by FIRMLY pushing the “RESET” button back in until you hear or feel a

distinctive “click”. IF THE GFCI FAILS TO RESET PROPERLY, DO NOT USE EITHER OUTLET OF THE DUPLEX

RECEPTACLE. Have the unit serviced by an authorized John Deere Customer Service Representative immediately.

3. High vibration or severe mechanical shock loads may cause the GFCIs to trip. IF EITHER GFCI TRIPS BY

ITSELF AT ANY TIME, reset it and perform test procedures 1 and 2.

4. Repeat steps 1-3 for the second GFCI.

WARNING: ALTHOUGH THE ABOVE TEST PROCEDURES WILL INDICATE PROPER GFCI OPERATION ON

AN UNGROUNDED OR IMPROPERLY GROUNDED GENERATOR, THE GENERATOR MUST STILL

BE GROUNDED PER THE GROUNDING INSTRUCTIONS LISTED ON PAGE 16 FOR THE GFCI TO

FUNCTION PROPERLY AND PROTECT THE USER FROM ELECTRICAL FAULTS.

Service

Year

Jan.

Feb. March April May

June July

Aug. Sept. Oct.

Nov.

Dec.

NOTE: Situations exist where a GFCI will not afford any protection against the hazards of electrical shock.

EXAMPLE: if a person touches two or more conductors from a damaged cord set and is not in direct contact

with the ground, he or she may receive a shock. Since there is no path to ground for a ground fault current to

flow through, the GFCI will not operate and serious injury may result.

The GFCI are merely an added safety feature. There are no substitutes for good safety precautions, correct

electrical practices and proper maintenance of cords, equipment and connections.