Rs-232c communication examples – JVC DLA-RS1 User Manual

Page 45

Advertising
background image

45

Getting Started

P

reparation

B

asic

Operation

S

ettings

Troubleshooting

Othe

rs

ENGLISH

This section shows the communication examples of RS-232C.

„

Operating command

„

Reference command

RS-232C Communication Examples

Type

Command

Description

Connection check

PC

 This unit: 21 89 01 00 00 0A

This unit

 PC: 06 89 01 00 00 0A

Checks connection

Power (On)

PC

 This unit: 21 89 01 50 57 31 0A

This unit

 PC: 06 89 01 50 57 0A

When power is turned on from standby mode

Power (Off)

PC

 This unit: 21 89 01 50 57 30 0A

This unit

 PC: 06 89 01 50 57 0A

When power is turned off (standby mode)
from power-on mode

Input (COMP.)

PC

 This unit: 21 89 01 49 50 32 0A

This unit

 PC: 06 89 01 49 50 0A

When video input is set to component

Remote Control

(MENU)

PC

 This unit: 21 89 01 52 43 37 33 32 45 0A

This unit

 PC: 06 89 01 52 43 0A

When the same operation as pressing the
[MENU] button on the remote control is made

Type

Command

Description

Power (On)

PC

 This unit: 3F 89 01 50 57 0A

This unit

 PC: 06 89 01 50 57 0A

This unit

 PC: 40 89 01 50 57 31 0A

When information on power-on mode is
acquired

Input (S-VIDEO)

PC

 This unit: 3F 89 01 49 50 0A

This unit

 PC: 06 89 01 49 50 0A

This unit

 PC: 40 89 01 49 50 30 0A

When information on S-VIDEO input is
acquired

DLA-RS1_EN.book Page 45 Wednesday, January 24, 2007 9:23 AM