The factory settings vary depending on the model.

RM-HP250AU : RTS system. *1

RM-HP250DE : 2-wire system, which uses the H and C

terminals. *1

An intercom connector is provided on the front panel of the
RM-HP250.
The volume level of the headset’s earphone can be adjusted
using the INTERCOM LEVEL control.

Intercom Input Connector (XLR 5 Pin)
Input connector for intercom headset. (Dynamic only)
Recommended headset: DT109 (Beyerdynamic)

Intercom

Intercommunications between operators are necessary in a system composed of multiple cameras
and remote control units.

Preparations and Main Functions

When the CALL button is pressed, the button light is lit and
the tally lamp on the camera blinks. Pressing the button again
turns off both the button light and the blinking of the camera’s
tally lamp.

Camera Operator Call

This function makes it possible to call the camera operator without using the intercom. The camera
operator is informed of the call by the blinking of the tally lamp on the camera.

The factory settings vary depending on the model.

RM-HP250AU : Contact supply mode *1

RM-HP250DE : Voltage supply mode *1

TALLY lamp will light up in red when PGM (Program)

terminal and C (Common) terminal are in the contact status
(RM-HP250AU) or when 2 points of rated voltage are ignited
(RM-HP250DE).

TALLY lamp will light up in green when PWW (Preview)

terminal and C (Common) terminal are in the contact status
(RM-HP250AU) or when 2 points of rated voltage are ignited
(RM-HP250DE).

Tally

The TALLY lamp on the front panel lights when signals are applied to the TALLY terminals on the
rear panel.

CALL

TALLY

INTERCOM

LEVEL

FULL AUTO

F1

SHUTTER

GAIN

F2

BARS

CALL button

2. CABLE

TALLY

PGM

PVW

C

INTERCOM

AUX VIDEO INPUT

GENLOCK INPUT

H

C

G

PGM (Program) terminal

PVW (Preview) terminal

C (Common) terminal

The tally lamp on the camera does not blink or light when
either the camera or the RM-HP250 are switched off.
When the CALL button of the camera is pressed, the CALL
button of RM-HP250 blinks in red.

NOTE

Signal

1

MIC (H)

2

MIC (C)

3

EAR (C)

4

EAR (H) – LEFT

5

EAR (H) – RIGHT

1

3

2

5

4

(Surface profile)

Examples of suitable headsets

DT109 (Beyerdynamic)
Headsets from other manufacturers with:
Microphone output impedance: 50

W to 200 W

Earphone input impedance: 50

W to 400 W

NOTE

Front Panel

CALL

TALLY

INTERCOM

LEVEL

FULL AUTO

F1

SHUTTER

GAIN

F2

BARS

RM-HP250AU Rear Panel

RM-HP250DE Rear Panel

INTERCOM LEVEL control

2. CABLE

Intercom connector

AC ` IN 230V` 50Hz

AC ` IN AC120V 60Hz

TALLY

PGM

PVW

C

INTERCOM

AUX VIDEO INPUT

GENLOCK INPUT

H

RTS

C

G

TALLY

PGM

PVW

C

INTERCOM

AUX VIDEO INPUT

GENLOCK INPUT

H

C

G

*1 If tally and intercom settings (for changing model from AU to DE or vice versa) are required, the setting of the internal circuitry

should be changed; consult the nearest JVC-authorized service agent.