ENGLISH

HOW TO USE EXTERNAL
CONTROL

ABOUT EXTERNAL CONTROL

This monitor is provided with an external control terminal. MAKE (make contact) or TRIG. (trigger) system can be selected by
the setting of REMOTE SYSTEM in the <SET-UP MENU>.
MAKE (make contact system) : The function is controlled by short-circuiting or disconnecting each control terminal with pin 15

(GND).

TRIG. (trigger system)

: The function is controlled by short-circuiting with pulses (for about 1 second) (short-circuit/open

with the 15th pin GND).

* The 14th pin (REMOTE ENABLE) is controlled with MAKE even though TRIG. is selected.

Note:
● When this monitor is externally controlled, the following buttons are disabled.

MAKE: INPUT-A and B, UNDER SCAN on the front panel.

*1 : OFF stands for disconnection, and ON stands for short-circuit.
*2 : Do not connect.
*3 : Setting REMOTE ENABLE to ON enables remote control from the REMOTE terminal.
*4 : INPUT REMOTE setting in the set-up menu (REMOTE SYSTEM shown only when MAKE is selected.)

For the D-sub pins 2 and 3, 2-pin or 1-pin control can be set with INPUT REMOTE in the set-up menu.
• 2-pin control: Only the specified signal line in INPUT-A or B is short-circuited.
• 1-pin control: Switches between INPUT-A and INPUT-B only with the 2nd pin of the D-sub connector.

OFF : INPUT A
ON : INPUT B

The Names and Functions of Terminals

No. Names

Functions

Operations (OFF p[ ON)

*

1

1

not used

*2

2

INPUT A

Changes the input to INPUT A

Not change

Change

*4

3

INPUT B

Changes the input to INPUT B

Not change

Change

*4

4

not used

*2

5

not used

*2

6

not used

*2

7

not used

*2

8

not used

*2

9

not used

*2

10

ASPECT

Changes the screen ratio to 16:9

4:3

16:9

11

UNDER SCAN

Makes the screen under-scan

Over-scan

Under-scan

12

not used

*2

13

not used

*2

14

REMOTE ENABLE Makes the external control from the

Invalid

Valid

*3

REMOTE terminal valid or invalid

15

GND

Used as a ground terminal

Connections

Connect (short-circuit) the 15th terminal (GND) to each of the 1st through 14th terminals in the
3-lines 15-pins D-sub connector. The functions of each terminal are listed below.

NOTES :
● When both INPUT A and INPUT B are selected (short-circuited) under the MAKE system, INPUT A has priority.

● To control INPUT A and INPUT B in MAKE mode, we recommend using the interlock switch, which turns off a switch when

another switch is turned on.