HOW TO USE EXTERNAL
CONTROL

Ⅵ ABOUT EXTERNAL CONTROL

This monitor is provided with an external control terminal. MAKE (make contact) or TRIG. (trigger) system can be selected by
the setting of REMOTE SYSTEM in the <SET-UP MENU>.
MAKE (make contact system) : The function is controlled by short-circuiting or disconnecting each control terminal with pin 15

(GND).

TRIG. (trigger system)

: The function is controlled by short-circuiting with pulses (for about 1 second) (short-circuit/open

with the 15th pin GND).

* The 14th pin (REMOTE ENABLE) is controlled with MAKE even though TRIG. is selected.

Note:
● When this monitor is externally controlled, the following buttons are disabled.

MAKE: INPUT-A and B, UNDER SCAN on the front panel.

*1 : OFF stands for disconnection, and ON stands for short-circuit.
*2 : Do not connect.
*3 : Setting REMOTE ENABLE to ON enables remote control from the REMOTE terminal.
*4 : INPUT REMOTE setting in the set-up menu (REMOTE SYSTEM shown only when MAKE is selected.)

For the D-sub pins 2 and 3, 2-pin or 1-pin control can be set with INPUT REMOTE in the set-up menu.
• 2-pin control: Only the specified signal line in INPUT-A or B is short-circuited.
• 1-pin control: Switches between INPUT-A and INPUT-B only with the 2nd pin of the D-sub connector.

OFF : INPUT A
ON : INPUT B

The Names and Functions of Terminals

No. Names

Functions

Operations (OFF p[ ON)

*

1

1

not used

–

–

–

*2

2

INPUT A

Changes the input to INPUT A

Not change

Change

*4

3

INPUT B

Changes the input to INPUT B

Not change

Change

*4

4

not used

–

–

–

*2

5

not used

–

–

–

*2

6

not used

–

–

–

*2

7

not used

–

–

–

*2

8

not used

–

–

–

*2

9

not used

–

–

–

*2

10

ASPECT

Changes the screen ratio to 16:9

4:3

16:9

11

UNDER SCAN

Makes the screen under-scan

Over-scan

Under-scan

12

not used

–

–

–

*2

13

not used

–

–

–

*2

14

REMOTE ENABLE Makes the external control from the

Invalid

Valid

*3

REMOTE terminal valid or invalid

15

GND

Used as a ground terminal

–

–

Connections

Connect (short-circuit) the 15th terminal (GND) to each of the 1st through 14th terminals in the
3-lines 15-pins D-sub connector. The functions of each terminal are listed below.

NOTES :
● When both INPUT A and INPUT B are selected (short-circuited) under the MAKE system, INPUT A has priority.

● To control INPUT A and INPUT B in MAKE mode, we recommend using the interlock switch, which turns off a switch when

another switch is turned on.
To control INPUT A and INPUT B in TRG. mode, we recommend using the return switch, which stays ON while pressed.

1

2

3

10

8

9

6

7

11

12

13

14

15

4

5

15