Mounting the lens – JVC KY-F70B User Manual

Page 21

Advertising
background image

E17

2.

KY-F

70B

CAMERA

DIGITAL

C-MOUNT

Mounting the lens

Follow the procedure shown below when mounting an auto-iris lens. For further details, see the
instruction manual of the lens and lens remote control.

Camera head

Thread section

Mount clamp ring

Lens

Male

Female

Lens remote control
Compatible lens remote control
FJINON, RMD-10, RMD-20

Compatible
zoom lens
FUJINON
S14

×7.3DA-D24

1.

Remove the lens mount cap. At this time, take caution so that dust do not enter inside the
mount.

2.

To mount the lens, lightly press the thread section of the lens mount onto the thread section
of the main unit, then turn the mount clamp ring slowly clockwise until it is securely tight-
ened.

MEMO

To change the position of the lens rotation:
ቢ First, turn the mount clamp ring counterclockwise (1/4 turns) with the lens facing you.
ባ Slowly turn the lens and after adjusting the position, retighten the mount clamp ring.

3.

Insert the camera cable of the lens into the lens connection terminal on the rear of the main
unit, then securely lock.
The iris control is made automatically from the camera.
When using a manual iris lens, set the IRIS MODE to MANUAL (

੬ page 50).

4.

When using the lens remote control, connect the lens control cable (female) to the remote
control.

When operating the lens iris manually by lens remote control connection, set IRIS MODE to
manual. (

੬ page 50)

CAUTION

• Perform mounting of the lens with the power of the camera turned OFF. Mounting with the power on

could result in damage.

• Lens is not included with this unit.

To avoid damaging the main unit, make sure that the lens mount of the lens to be

used is 4mm or less.

Lens

4mm or less

3.

Lock

4.

Lock

Advertising