Specifications of the jp-24/jp-24f – Jackson Hot Water Sanitizing Undercounter Dishmachines JP-24F User Manual

Page 7

Advertising
background image

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

SECTION 1: SPECIFICATION INFORMATION

SPECIFICATIONS of the JP-24/JP-24F

2

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

30

DISHES PER HOUR

600

GLASSES PER HOUR

600

OPERATING CYCLE (SECONDS)

WASH TIME

82

DRAIN TIME

28

RINSE TIME

10

TOTAL CYCLE TIME (MINUTES)

2

5 MINUTE TIMER OPERATING CYCLE (SECONDS)

WASH TIME

262

DRAIN TIME

28

RINSE TIME

10

TOTAL CYCLE TIME (MINUTES)

5

TANK CAPACITY (LITERS) (GALLONS)

WASH TANK (21.5) 5.65

TEMPERATURES

WASH --- (MINIMUM) (65.6°C) 150°F

RINSE --- (MINIMUM) (82.2°C) 180°F

WATER REQUIREMENTS

INLET TEMPERATURE

(82.2°C) 180°F

GALLONS PER HOUR

(198.7L) 52.3

WATER LINE SIZE I.P.S. (Minimum) (1.27 cm) 1/2”

DRAIN LINE SIZE I.P.S. (Minimum) (3.81 cm) 1 1/2”

FLOW PRESSURE P.S.I.

20

A5

FLOW, GALLONS PER MINUTE

(27L) 7.1

ELECTRICAL REQUIREMENTS

WASH MOTOR HP

3/4

NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip cir-
cuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is dis-
played here. Always verify with your electrical service con-
tractor that your circuit protection is adequate and meets all
applicable national and local codes. These numbers are pro-
vided in this manual simply for reference and may change
without notice at any given time.

JP-24/JP-24F:

RINSE

TYPICAL

HEATER

TOTAL ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208 1 50 900KW

12

15 AMP

230 1 50

1100KW

12

15 AMP

208 1 60 900KW

10

15 AMP

230 1 60

1100KW

10

15 AMP

NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.