Jotul GF 3 BV User Manual

Page 10

Advertising
background image

GAS CONVERSION:

The Allagash B-Vent gas stove is shipped from

the factory equipped as a NATURAL GAS unit;

However, the stove is shipped with the necessary

gas conversion kit to convert the stove to burn

PROPANE GAS. These kits contain all the

necessary components needed to complete the

task and ensure safe operation, including labeling

that must be affixed to the stove.

WARNING:

THE CONVERSION KIT IS TO BE INSTALLED BY

AN AUTHORIZED JØTUL SERVICE TECHNICIAN

IN

ACCORDANCE

WITH

THE

MANUFACTURER’S INSTRUCTION AND ALL

CODES AND REQUIREMENTS OF THE

AUTHORITY HAVING JURISDICTION. FAILURE

TO FOLLOW THESE INSTRUCTIONS COULD

RESULT IN SERIOUS INJURY OR PROPERTY

DAMAGE. THE QUALIFIED AGENCY

PERFORMING THIS WORK ASSUMES

RESPONSIBILTY FOR THIS CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED OUT IN

ACCORDANCE WITH THE REQUIREMENTS OF

THE PROVINCIAL AUTHORITIES HAVING

JURISDICTION AND IN ACCORDANCE WITH

THE REQUIREMENTS OF THE CAN1-B149.1 AND

.2 INSTALLATION CODE.

Cet equipement de conversion sera installe par

une agence qualifiee de service conformement aux

instructions du fabricant et toutes exigences et

codes applicables de l’autorises avoir la

juridiction. Si l’information dans cette Instruction

n’est pas suivie exactement, un fey, explosion ou

production de protoxyde de carbone peut resulter

blessure personnelle de vie. L’agence qualifiee

de service est esponsable de l’installation n’est

pas propre et complete jusqu’a l’operation de

l’appareil converti est cheque suivant les criteres

etablis dans les instructions de proprietaire

provisionnees avec l’equipement.

Tools required:

1/4” Nut driver, 7/16” and 1/2” open end

wrench or deep well socket, 4mm allen

wrench, Torx t20 or slotted screwdriver.

Included in the conversion kit:

1 regulator tower labeled for propane

3 regulator tower screws

1 burner orifice (#54 LPG)

1 pilot orifice ( #30 for LPG, #51 for NG)

Label A - to be completed and adhered to the

back of the stove.

Label B - to adhere to the stove’s rating plate.

IMPORTANT:

If the forced air blower kit is installed, be sure

to unplug blower before proceeding with this

conversion. Any gas supply must be turned

off and disconnected from the valve.

Conversion instructions are also shipped in the

stove with the conversion kit.

Gas Conversion Procedure

1. Turn off gas supply to the stove.

2. Lift off top plate (5).

3. Release the glass clips atop the stove and

slowly lift glass panel (10) up and out of track.

4. Remove the log set (12) using care not to

scratch or damage logs.

5. Lift out the log support (14). Remove the air

divider (15) by lifting the right side and slowly

rotating forward.

6. Remove burner tube (13): Using a ¼” nut

driver remove the two screws securing the

burner tube (13) to the stove bottom. Lift out

the burner tube.

7. Change the main burner orifice. Using a ½”

open end wrench or deep well socket remove

the burner orifice and replace with the

appropriate orifice, supplied in the kit.

10

Advertising