Chapter 5---Troubleshooting

5-3

Model 330, 340SC, and 370SC Service Manual

LED

On-Screen Text

Description

x

Problem with decoder module data.

y

Problem with decode input.

#

Loss of horizontal sweep detected.

Codes indicating a software bug—system should keep running.

G

Internal error code not recognized.

H

Incoming command not recognized.

J

Internal password control code bad.

K

DAC reference not recognized.

L

Timer table reference not valid.

M

IIC reference not recognized.

N

RTG reference not recognized.

P

Internal convergence axis reference invalid.

Q

Internal channel parameter reference not recognized.

R

Internal convergence data index invalid.

5.2 Power-On

Codes

The projector performs a series of operations when power is turned on. Codes for
these operations are shown on a LED display at the rear of the projector.
Operations are divided into two (2) sets:

1.

The first (1

st

) set occurs when standby power is applied. For example, the

projector is plugged into a proper outlet and the circuit breaker on the side
of the projector is ON.

2.

The second (2

nd

) set takes place when the user issues a “power-on”

command. For example, presses “Control-P” on a VT-100 terminal or
“POWER ON” on the I/R or tethered remote.

First Set

The first (1st) set of operations occurs when the +5volts is activated to the SCB
prior to applying power to the projector (standby mode). After the +5volts is
applied, the LED should display a zero or #—if not displayed, there is a problem
with the SCB.

Verify the following conditions:

1.

Verify that +5volts and +24volts standby LEDs are lit. If STB +5volts and
+24volts are not present, verify that the projector is plugged into a proper
outlet and that the circuit breaker on the right side of the projector is on. If