Stove and Vent Clearance
Requirements

Minimum Clearances from the Stove to Combustibles:
See figs. 2-4.
Rear:

0” (0 mm)

Ceiling:

25” (635 mm)

Corner:

2” (50 mm)

Right Side: 3” (76 mm)
Left Side:

10” (254 mm)

- for access to Lighting Instruction plate

Minimum Clearances from the Vent Pipe to Combus-
tibles:
Horizontal Run:
Off the top of the pipe 2”

(50 mm)

Off the sides and bottom

1”

(25 mm)

Vertical Run:
All sides

1”

(25 mm)

Alcove Installation

Maximum Alcove Depth: 24” (610 mm)
Minimum Alcove Width: 34” (864 mm)
Minimum Ceiling Height: 47” (1094 mm)

* Allow 10” on left side of the appliance for complete

access to the lighting instructions and control valve.

CLEARANCE TO REAR WALL IS= (0”) ZERO CLEARANCE

3”

(80 mm)

Right Side

Figure 3. Parallel Installation Clearances.

2”

50 mm

2”

50 mm

Figure 4. Corner Clearances.

10” *

(250 mm)

Left Side

1” deep trim

must be 4”

(102 mm)

off the top

of the stove.

Figure 2. Mantel and Trim Clearance
specifications.

24”or greater

Mantel Depth or Ceiling

12” or less

6” or less

4”or less

6”

152 mm

9”

229

mm

16”

406 mm

25”

635 mm