Shd-60 troubleshooting – Stellar Industries V480 User Manual

Page 27

Advertising
background image

Troubleshooting 23

Problem

Compressor locks up at 110

psi and higher while under

load:

Note: When checking

hydraulic pump flow, make

sure the air tank is closed

and the compressor is

running.

Compressor will not

operate:

Possible Cause

Weak Hydraulic Motor.

Faulty Hydraulic Pump.

Oil Pressure is low.

Air receiver is full.

12 Volt power is not going to the line

side of the pressure switch.

Faulty Pressure Switch.

Hydraulic Lines not installed correctly.

Air Couplers or hoses are blocked.

Inline Check-Valve is leaking.

Faulty Solenoid Valve.

Compressor is locked up.

Hydraulic motor malfunctioning.

Hydraulic pump malfunctioning.

Solution

If the Hydraulic pump is supplying the

recommended amount of fluid to the hydraulic

motor, replace the hydraulic motor.

If the pump pressure is below the recommended

GPM, replace the Hydraulic pump if necessary.

If the oil pressure gauge is reading in the red

area, the oil pressure is low. See the Low Oil

Pressure entry in this troubleshooting section.

Drain and activate pressure switch.

If there is no power going to the line side of the

pressure switch, trace the wire back to the

power source.

If there is no power going to the solenoid valve,

replace the pressure switch.

Reinstall hydraulic lines.

Locate and remove restriction.

Disassemble, clean, and reinstall or replace.

If there is power going to the pressure switch,

press down on the solenoid valve bypass button.

If the compressor starts to operate, replace the

solenoid valve.

Remove the coupler and lovejoy between the

compressor pump and the hydraulic motor. Turn

the compressor over by hand. If the compressor

turns over freely, the pump is ok. This indicates

there is a possible hydraulic problem.

Inspect and repair.

Check flow and pressure settings.

SHD-60 Troubleshooting

If symptoms of poor performance develop, the following chart can be used as a guide to

investigate and correct the problem. When diagnosing faults in operations of the air

compressor, always check that the hydraulic power source is supplying the correct

hydraulic flow and pressure that is listed in the compressor specification section of this

manual. Note: To Operate, the American Eagle SHD-60 Compressor needs 10 GPM and

1800 PSI System Pressure.