Technical specifications – Symbol Technologies LS 400XI User Manual
Page 27

4-2
LS 400Xi Product Reference Guide
Technical Specifications
Table 4-1. Technical Specifications
Item
Description
Power Requirements*
IBM 46XX/Synapse
RS-232C/Synapse
Low Power
4.8 to 14 VDC (max) 200 mA @ 5V typical
4.8 to 14 VDC (max) 180 mA @ 5V typical
4.8 to 14 VDC (max) 2 mA @ 5V typical
Decode Capability
The LS 400Xi can be programmed to decode the following
code types: UPC/EAN, Bookland EAN, Code 39, Code
39 Full ASCII, Trioptic Code 39, Code 93, Codabar,
Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5,
MSI Plessey, and PDF417. Set code length(s) for any linear
code type. The LS 400Xi can auto-discriminate between all of
the above code types except for Code 39 and Code 39 Full
ASCII. Transmission of decoded information will depend on
the capabilities of the attached terminal.
Beeper Operation
User-selectable: Enabled, Disabled
Scan Repetition Rate
100 scans/sec (bidirectional)
Scan Angle
30°
Roll (Skew) Tolerance
± 10˚ from normal
Pitch
± 65˚ from normal
Yaw
± 60˚ from normal
1-D Decode Depth of Field
LS 400Xi 1-D Decode Zone on page 4-4
2-D Decode Depth of Field
LS 400Xi 2-D Decode Zone on page 4-5
Print Contrast Minimum
20% absolute dark/light differential, measured at 675 nm.
*For direct host power connection, make sure the host terminal supplies sufficient power for the
specified operation. Symbol is not responsible for damage to host equipment or system mis-
operation due to an insufficient power condition.