Seco-larm, U.s.a., inc, Warranty – SECO-LARM USA ENFORCER ST-1206-1.5AQ User Manual

Page 2: Notice

Advertising
background image

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

®

U.S.A., Inc.,

U.S.A., Inc.,

U.S.A., Inc.,

U.S.A., Inc.,

U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

Website: www.seco-larm.com

E-mail: [email protected]

MuST12-2406Q_084.pmd

Order Part #763-074-8%

PITSW1

WARRANTY:

This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to

the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.

This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty

installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable

for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE:

The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and

improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.

Transformer selection table:

To program DC voltage output:

NOTE:

a. Before connecting any external devices, temporarily power up the unit and measure the DC output voltage

to avoid damage to devices. Then disconnect power before connecting external devices.

b. LED status — for ST-1206-1.5AQ, Red LED on indicates connections to AC power.

for ST-2406 series, see Table 3.

WARNING:1. Using a higher AC input than recommended may damage the unit.

2. When a power supply/charger is used at its maximum load for an extended

period of time, the heatsink portion of the power supply/charger will be very hot.

3. DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY’S PC BOARD.
4. Measure DC output before connecting devices.

Table 3:

Green LED Red LED

Status

ON

ON

Normal

OFF

ON

No VAC input

ON

OFF

No VDC output

OFF

OFF

No VAC input and VDC output

LED status for ST-2406 series:

* For ST-1206-1.5AQ model. See point 2 under Installation.

3. Connect the wirings to their respective terminals (see Figure 1 and 2).

Voltage

6V

ON

12V

24V

OFF

OFF

SW1

SW2

OFF
OFF

ON

6VDC

12VDC

24VDC

12VAC/20VA

16VAC/40VA

24-28VAC/210VA

ST-UV24-W50Q

24VAC/50VA

ST-UVDA-W100Q
24-28VAC/100VA

ST-UVDA-W100Q

24-28VAC/100VA

ST-2406-3AQ

16VAC/100VA

ST-UV16-W100Q

16VAC/100VA

ST-UVDA-W180Q

ST-UV16-W100Q

ST-UVDA-W180Q

24-28VAC/180VA

24-28VAC/180VA

24-28VAC/180VA

ST-UVDA-W180Q

ST-UVDA-W180Q

24-28VAC/180VA

ST-UVDA-W180Q

24-28VAC/180VA

28VAC/350VA

ST-2406-5AQ

ST-2406-7AQ

ST-2406-10AQ

ST-2406-2AQ

Output voltage

To back-up battery positive (+) input
To back-up battery negative (-) input

To alarm or access control
panel VDC negative (-) input

To alarm or access
control panel VDC
positive (+) input

To alarm or access control
panel VDC negative (-) input

AC

DC

BAT

+

-

+

-

Figure 2 – ST-2406 Series wiring diagram

To Class-II
transformer
VAC outputs

Red DC Output LED

Green AC Input LED

Figure 1 – ST-1206-1.5AQ wiring diagram

To alarm or access control
panel VDC positive (+) input

AC

DC O/P

I/P

1

2

3

4

(black)

(red)

To Class-II
transformer
VAC outputs

Wire loop

Red Led

indicator

ST-1206-1.5AQ

12VAC/20VA

16VAC/40VA

ST-UV24-W50Q

24VAC/50VA

N/A

To back-up battery negative (-) input
To back-up battery positive (+) input

ST-UV28-T350Q

Table 1:

Table 2: