2

7

3. Attach the flow calibrator bottle to the wand:
a. Remove the nozzle, cap and

filter from the spray wand.

b. Mount the flow calibrator

cover to the spray wand.

c. Reinstall the nozzle, filter

and nozzle cap.

d. Screw the flow calibrator

bottle into the cover.

4. Using the flow calibrator bottle:
a. Operate the pump handle to

maintain spray system pres-

sure as you would when

applying chemicals.

b. Hold the wand at your normal working position and spray

into the bottle while walking the distance identified in step 2

above.

c. Place the bottle on a level surface and observe the liquid

level visible through the side of the bottle. Match the liquid

level to the l/acre (liter per acre) scale on the calibration

bottle.

d. Multiply the l/acre (liter per acre) reading identified in

step 4-c by .264 to determine your application coverage rate

in gallons per acre.

e. Empty the bottle contents back into the sprayer tank.

NOTE:

For improved accuracy in calibrating your application coverage,

repeat steps 4-a through 4-e and average the results.

1. Hold the wand

at the working

height and spray

a test pattern to

measure the appli-

cation band width.

2. Based on the band

width, identify from the

table below the walking

distance required to calibrate

the sprayer.

Carefully read the labels on chemical contain-

ers prior to use. Chemicals are classified in four

categories of toxicity:

Category I, High Toxicity, Red label

Category II, Moderate Toxicity, Yellow label

Category III, Low Toxicity, Blue label

Category IV, Light Toxicity, Green label

There are unique handling recommendations

for each category, and you should familiarize

yourself with them.

Always wear clothing and safety equipment that

will provide appropriate protection against the

materials you are handling. Equipment may

include, but not be limited to:

Long sleeve shirt

Impermeable apron or coverall

Impermeable gloves and boots

Wide-brim hat

Protective mask equipped with

appropriate filters

Do not eat, drink, or smoke while handling

chemicals or while you are spraying. Always

handle chemicals in a well ventilated area while

wearing appropriate protective clothing and

safety equipment. DO NOT STORE OR TRANS-

PORT CHEMICALS WITH FOOD OR MEDI-

CINES, AND NEVER REUSE A CHEMICAL

CONTAINER FOR ANY OTHER PURPOSE.

Keep chemicals out of the reach of children,

animals, or other unauthorized people. When

not in use, store chemicals in a safe place. Never

blow through nozzles, valve, pipes or any other

component by mouth!

When handling chemicals and when spraying,

make sure you are operating in accordance with

local, state, and federal environmental protection

rules and guidelines. Do not spray in very hot

or windy conditions. DO NOT POLLUTE THE

ENVIRONMENT!

After spray application, take a thoroughly cleans-

ing shower using plenty of water and soap, then

change into clean clothes. Protective clothing

and safety gear should also be cleaned after each

use. IN CASE OF EXPOSURE TO DANGER-

OUS CHEMICALS, seek a physician immedi-

ately and be prepared to provide the label from

the chemical container.

AIR

WATER

EARTH

Cover

Filter

Nozzle

Calibrator

Bottle

Band width

1.6 ft

2.3 ft

3.3 ft

4.0 ft

5.0 ft

0.5m

0.7m

1.0m

1.2m

1.5m

Distance to walk

165 ft 120 ft

80 ft

70 ft

55 ft

50.0m 35.7m 25.0m 20.8m

Calibrating the Sprayer

Safety Precautions

Nozzle

Cap

Tip

Filter

Swirl Core

Disc

Filter

Tip

The spraying angle is

changed by turning

the tip

Cap

Cap

Adjustable Cone

Nozzle

Cone Nozzle

Flat Fan Nozzle

Typical Nozzle Assemblies

(Requires optional flow calibrator bottle, P/N 646901)

Wand

Illustrated Parts List (SP150)

No. Description

Part Number

Qty.

02

Strap Assembly

925198

1

03

Strap 1800mm

901018

1

04

Shoulder Protector SP-150

917477

1

05

Shoulder Strap Buckle

502757

2

06

Tank Lid Assembly

922550

1

07

O-Ring, Tank Lid

8000778

1

08

Diaphragm Valve (viton)

964270

1

10

Cylinder Assembly

285262

1

11

Piston Cup

285270

1

12

Bushing

285288

2

13

Cylinder Cap

285296

1

14

Pumping Handle

N/A

1

15

Pumping Handle Assembly

285312

1

16

O-ring ORI-110

8000236

1

17

Dip Tube With Hose

9012246

1

18

Screw Cap S-20

942193

1

19

Trigger

568972

1

20

Trigger Valve Handle

909192

1

21

Hose Ferrule

920470

1

22

Trigger Valve Body

909283

1

23

Trigger Valve Needle Assembly

105239

1

24

Trigger Valve Cap With Seal

996058

1

25

Trigger Valve Assembly

568782

1

26

Cone Packing

909309

2

27

Screw Cap

915744

2

28

Tube

336263

1

29

Elbow

635276

1

30

Nozzle Filter

592139

1

35

Ajustable Cone Nozzle (Red)

015024

1

36

Extension Assembly

568873

1

37

Spray Wand Assembly

568774

1

38

Seal Kit (Optional)

927850

1