1-6

BKDW-515

1-8. Extension of Control Panel

Notes when connecting the two BKDW-515

. Setup Setting Data

The Current Setup setting data inside of the BKDW-515

is transferred to the VTR just after the communication
between the BKDW-515 and VTR are established. The

ALARM LED on the front panel blinks during the data
communication is incomplete.

When the two BKDW-515 are connected to a single
VTR, last setting data out of two is written over the

former data as the effective setting data.
If the two BKDW-515 with different data setting are

connected to a single VTR, and if the power is turned to
ON simultaneously, un-defined setting data will be sent

to the VTR. Therefore, first, connect either BKDW-515
to a single VTR for storing the Current Setup setting data

in bank memory of VTR or in the memory card before-
hand. After that, connect the two BKDW-515 to a single

VTR, turn on the power of both BKDW-515, then copy
the memorized data into Current Setup. The Current

Setup setting data among the two BKDW-515 and VTR
will be automatically renewed to keep the contents of

data identical.

. VTR Control

Control of VTR is set by an INT/EXT selection of the

System Setup Panel and ITEM 117 “CONTROL PAN-
EL SELECTION” of the setup menu.

Notes when connection the BKDW-514 and
BKDW-515 (Extender)

When connecting the BKDW-514 and BKDW-515

(Extender) to VTR, be sure to turn on the power of
BKDW-515 first. If the power of BKDW-515 is in off,

start up a menu system (SETUP MENU BANK 1/2/3/4:
BANK 4 is effective from SYS-V3.01 and later) of DVW-

500 series, therefore the contents set with BKDW-515 can
not be used. If MENU lamps 1, 2, and 3 on the indicator

section of VTR’s upper control panel are off, the contents
set with BKDW-515 can be used.

Pay attention when pressing the MENU button without
pressing the SET button after renewing the Setup setting

data with BKDW-514, because renewed data will be
validated if both BKDW-514 and BKDW-515 have been

connected regardless of SET button. However, renewed
data will be invalidated if the only BKDW-514 has been

connected.