Is the maximum value and v, Is the average value of v, And v – Sony ICX418ALB User Manual

Page 9: 2 assuming v, 5) substrate clock waveform

Advertising
background image

– 9 –

ICX418ALB

(3) Horizontal transfer clock waveform

(4) Reset gate clock waveform

V

RGLH

is the maximum value and V

RGLL

is the minimum value of the coupling waveform during the period from

Point A in the above diagram until the rising edge of RG. In addition, V

RGL

is the average value of V

RGLH

and

V

RGLL

.

V

RGL

= (V

RGLH

+ V

RGLL

)/2

Assuming V

RGH

is the minimum value during the period twh, then:

V

φ

RG

= V

RGH

– V

RGL

Negative overshoot level during the falling edge of RG is V

RGLm

.

(5) Substrate clock waveform

100%

90%

10%

0%

V

SUB

tr

tf

twh

φ

M

2

φ

M

V

φ

SUB

tr

twh

tf

90%

10%

twl

V

φ

H

V

HL

Point A

twl

V

φ

RG

V

RGH

V

RGL

V

RGLH

RG waveform

V

RGLL

H

φ

1

waveform

twh

tr

tf

+2.5V

V

RGLm

V

RGL

+ 0.5V

Advertising