Declaration of conformity, Usa-fcc class a, European union – Sun Microsystems SUN FIRE X2270 User Manual

Page 21: Usa—fcc class a

Advertising
background image

xxi

Declaration of Conformity

EMC

USA—FCC Class A

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This equipment may not cause harmful interference.
2. This equipment must accept any interference that may cause undesired operation.

European Union

This equipment complies with the following requirements of the EMC Directive 2004/108/EC:

Compliance Model Numbers:

3012H, 3012W

Product Family Name:

Sun Fire X2270 Server

As Telecommunication Network Equipment (TNE) in both Telecom Centers and Other Than Telecom Centers per (as applicable):
EN 300 386 V1.3.3 (2005-04) Required Limits:
EN 55022:2006

Class A

EN 61000-3-2:2000 +A2:2005

Pass

EN 61000-3-3:1995 +A1:2001

Pass

EN 55024:1998 +A1:2001 +A2:2003 Required Limits:

IEC 61000-4-2

6 kV (Direct), 8 kV (Air)

IEC 61000-4-3

3 V/m 80-1000 MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz

IEC 61000-4-4

1 kV AC and DC Power Lines, 0.5 kV Signal Lines

IEC 61000-4-5

2 kV AC Line-Grid, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor Signal

Lines > 10m

IEC 61000-4-6

3 V

IEC 61000-4-11

Pass

As Information Technology Equipment (ITE) Class A per (as applicable):
EN 55022:2006

Class A

EN 61000-3-2:2000 +A2:2005

Pass

EN 61000-3-3:1995 +A1:2001

Pass

EN 55024:1998 +A1:2001 +A2:2003 Required Limits:

IEC 61000-4-2

4 kV (Direct), 8 kV (Air)

IEC 61000-4-3

3 V/m

IEC 61000-4-4

1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines

IEC 61000-4-5

1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines

IEC 61000-4-6

3 V

IEC 61000-4-8

1 A/m

IEC 61000-4-11

Pass