Commissioning

1. Unwind all of the power cable from the power

cable retainer 7.

Note:

Ensure that the thermostat 3 and the heat level
switch 2 are standing at MIN resp. 0.

2. Insert the power plug into a wall power socket.
3. Place the heat level switch 2 at “III” and the

thermostat 3 at MAX. The control lamp “Power”
1 glows.

Important:

With the heat level switch 2 you can regulate how
quickly the appliance warms up. If you wish to heat
it up particularly quickly, select heat level “III”, if a
slow warming up is preferred, select heat level “I”.
Using the thermostat 3 you can set it to the desired
temperature.

4. When the desired room temperature has been

reached, slowly turn the thermostat 3 back until
a quiet “click” is heard and the control lamp
“Power” 1 extinguishes. The momentary room
temperature will now be retained. It could be
that every now and then the control lamp
“Power” 1 switches itself on and then back off.
This means that the programmed room tempera-
ture had fallen below this level for a short period
and the appliance had warmed itself back up.

Note:

If you want to heat a room up particularly quickly,
activate additionally the warm air switch 4.
When the warm air switch 4 is positioned at ON,
the warm air control lamp 4 glows and warm air is
blown through the warm air outlet 5 into the room.

5. If you wish to switch the appliance off, first place

the warm air switch 4 at the position OFF. Next,
turn the heat level switch 2 to “0” and then the
thermostat 3 to MIN.

6. Remove the plug from the wall power socket.

Frost protection function

You can programme this oil radiator so that, if the
room temperature falls near to 0°C, it switches itself
on and begins to radiate heat automatically:
1. Insert the power plug into a wall socket.
2. Position the heat level switch 2 at “I”, “II” or

“III”, and the thermostat 3 at MIN.

The oil radiator will now switch itself on if the tempe-
rature falls near to 0°C. When the temperature rises
above 0°C, the oil radiator switches itself off automati-
cally. The oil radiator will switch on and off periodically
to maintain the room temperature above 0°C.

Cleaning and care

Injury hazard

Allow the appliance to cool down before cleaning
it! Risk of Burns!
Remove the power plug from the wall socket.
There is a risk of electric shock!

Clean the appliance with a lightly moist cloth. For
stubborn soiling use a mild detergent on the cloth.

Attention!

Do not use any aggressive, abrasive or chemical
cleaning agents. These could damage the surfaces.

IB_54370_SOR2600A1_LB6.qxd 16.07.2010 13:04 Uhr Seite 4