Sentry Industries Sentry 2.0 User Manual

Sentry 2.0, Digital temperature controller, Complete operating instructions

Advertising
background image

1

Sentry 2.0

Digital Temperature Controller

Complete Operating Instructions

See pages 28-29 for instructions on upgrading your DTC

100, 600, 800 or 1000 series board to the Sentry.

Delay (pg 6)

From IdLE, press 3.

Enter time in hours:minutes.

Delays the start of firing.

Program Review (pg 6)

From IdLE or during

firing, press 6.

Shows the program that is

loaded in memory and ready to

fire, or the one that is firing.

Cone Table & Skip

Segment (pg 7)

From IdLE or during

firing, press 9.

From IdLE, shows tempera-

ture for the cone you enter.

While Firing: In Ramp-Hold,

skips to the next ramp. In

Cone-Fire, skips out of

Pre-Heat or Hold.

Stop/Back (pg 7)

Press during firing or

programming.

Stops a firing. In Options,

takes you back to IdLE.

During programming,

takes you back one step

each time key is pressed.

Options (pg 17 - 21)

From IdLE, press 0. Press

Enter for option displayed.

Cone-Fire Options

SPd

Speed Change the speed

of a Cone-Fire program beyond

the Fast, Medium, or Slow.

OFST

Cone Offset Adjust con-

troller to a witness cone.

FAN

Vent Fan Selects when

the vent fan will operate. (Special

option not on all kilns.)

Standard Options

TCOS

Thermocouple Offset

Calibrate the thermocouple

temperature.

CHG-

Select °F or °C.

TC

Thermocouple Type Se-

lect Type K, S or R.

AOP

AOP Outlet Select vent

fan or alarm. This is a special op-

tion not on all kilns.

Alarm (pg 6)

From IdLE or during

firing, press 7.

Enter a temperature. When

alarm sounds during firing,

press Enter.

Present Status (pg 6)

Press 5 during firing.

Shows the segment that is

currently firing. Works in

both Ramp-Hold and

Cone-Fire.

Cone-Fire (pg 8-11)

From IdLE, press 1.

Available only on ceramic

kilns. Fires to a pyrometric

cone. Enter cone, speed,

pre-heat, hold, and slow cool.

Add Time (pg 6)

During firing, press 2.

Each additional key press

adds five minutes to a hold.

It works in both Ramp-Hold

and Cone-Fire.

Ramp-Hold (pg 12-15)

From IdLE, press 4.

Select stored program (1 - 4).

Enter rate, temperature, and

hold for each segment.

Enter/Start (pg 7)

Press Enter/Start after each

step in programming a firing.

Press Enter/Start once to be-

gin the firing.

Id

Computer ID Select identi-

fication number for output to a

computer.

TEdE

Temperature Deviation

Set temperature sensitivity of er-

ror codes.

SFTY

Maximum temp.

ELEC

Electronics Temp.

Check board for overheating.

LOCK

Program Lock Make a

program tamper-proof.

CFG

Configuration Code

For technicians.

SOFT

Software Version

For technicians.

TEST

Element Test Diagnos-

tics tool for checking elements.

RST

Reset Removes cone

and thermocouple offsets, etc.

Multiple Zone Options

DIFF

Difference Largest

temperature difference be-

tween any two zones.

CAdJ

Center Adjustment

Change center heat of some

two-zone kilns.

T123

Zone Tempera-

tures Shows temperature of

each zone.