21 at+cind indicator control, 21 at+cind, Indicator control – Sony Ericsson GM47 User Manual

Page 115

Advertising
background image

3. CONTROL AND STATUS

115

LZT 123 7263 R1C

3.21 AT+CIND

Indicator Control

Used to set the values of ME indicators. <ind> value 0 means that the
indicator is off (or in state which can be identified as “off” state), 1
means that indicator is on (or in a state which is more substantial than
“off” state), 2 is more substantial than 1, and so on. If the indicator is a
simple on/off style element, it has values 0 and 1. The number of
elements is ME specific. If the ME does not allow setting of indicators
or it is not currently reachable, +CME ERROR: <err> is returned. If a
certain indicator is not writable, it cannot be set. If the parameter is an
empty field, the indicator will keep the previous value.

Test command returns pairs, where string value <descr> is a maximum
16 character description of the indicator and compound value is the
allowed values for the indicator. If ME is not currently reachable,
+CME ERROR: <err> is returned (refer to GSM 07.07).

Description

Command

Possible Responses

Set Indicator

Control

AT+CIND=[<ind>

[,<ind>[,…]]]

• +CME ERROR: <err>
• OK

• ERROR

Show the current

setting

AT+CIND?

• +CIND: <ind>,<ind>,…

• +CME ERROR: <err>
• OK
• ERROR

Show if the

command is

supported

AT+CIND=?

• +CIND: (<descr>,(list of

supported <ind>s)),

(<descr>,(list of supported

<ind>s)),…

• +CME ERROR: <err>

• OK
• ERROR

<ind>

Description

Integer type

Value shall be in range of corresponding <descr>

<descr>

Description

“signal”

Signal quality (0-5)

“service”

Service availability (0-1)

“sounder”

Sounder activity (0-1)

“message”

Message received (0-1)

“call”

Call in progress (0-1)

“roam”

Roaming indicator (0-1)

“sms full”

A short message memory storage in the MT has become full

(1), or memory locations are available (0); i.e. the range is

(0-1)

Advertising