Flue terminal clearances – State Models: 305 User Manual

Page 25

Advertising
background image

305, 505, 705 Indoor Manual

25

Flue Terminal Clearances (

ANS Z21.10.3 ● CSA 4.3)

INSIDE
CORNER DETAIL

FIXED
CLOSED

OPERABLE

FIXED
CLOSED

OPERABLE

B

B

B

A

J

B

M

C

F

B

B

E

D

L

G

A

H

K

I

1

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves
both dwellings.

2

Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the
requirements of the gas supplier.

X

V

AIR SUPPLY INLET

VENT TERMINAL

AREA WHERE
TERMINAL IS NOT
PERMITTTED

Ref

Description US

Installations

A

Clearance above grade, veranda, porch, deck, or balcony

12 inches (30 cm)

B

Clearance to window or door that may be opened

12 inches (30 cm)

C

Clearance to permanently closed window

*

D

Vertical clearance to ventilated soffit, located above the terminal
within a horizontal distance of 2 feet (61 cm) from the center line
of the terminal

*

E

Clearance to unventilated soffit

*

F

Clearance to outside corner

*

G

Clearance to inside corner

*

H

Clearance to each side of center line extended above meter/
regulator assembly

*

I

Clearance to service regulator vent outlet

*

J

Clearance to nonmechanical air supply inlet to building or the
combustion air inlet to any other appliance

12 inches (30 cm)

K

Clearance to a mechanical air supply inlet

3 feet (91 cm) above if within

10 feet (3 m) horizontally

L

Clearance above paved sidewalk or paved driveway located on
public property

*

M

Clearance under veranda, porch, deck, or balcony

*

Advertising
This manual is related to the following products: