Note:

-

The control panel cannot be armed if there are triggered sensors. Make sure

all sensors are in closed position, i.e. (close all doors, windows, no movement
should be detected etc).

-

The control panel can be armed if there are sensors with low battery or failure

warning.

2. After pressing the “ARM” button, the “ARM” LED will flash and you will have 45

seconds to leave the premises, this is called the exit delay. You will hear
beeping during the exit delay interval. The beeping rate will change from slow
to fast, the faster the beep rate, the less time you have left to leave the premises
before the siren sounds.

3. When the exit delay expires, the control panel will announce “System Armed”,

beeping will stop and the ARM LED will be on steadily. This indicates the
system is now armed.

Note:
The control panel can also be armed remotely when nobody is home, with a touch
tone phone. Please refer to “Remote Operation by Telephone” on page 24

.

Disarming the system

If a sensor is triggered while the control panel is armed, such as entering a house
with an armed control panel, an entry delay will be triggered. User is allowed to
disarm the control panel during the 30-second entry delay. If the control panel is
not disarmed within 30 seconds, siren will sound immediately and emergency
calls will be made. To disarm the control panel, follow the instructions below.

1. During the entry delay, the system will beep for 30 seconds, the ARM LED will

flash during this entry delay interval. The faster the beep, the less time you
have left to disarm the control panel before the siren sounds.

18

OPERATION

1. Entering the premises

will trigger the entry
delay.

2. Enter password within

30 seconds or press the
disarm button on the
keychain remote.

3. Once the system is

disarmed, the Arm
LED will be off.

OR

Beep Beep

Entry delay 30 seconds

Arm LED off

System
Disarmed

Beep Beep

Arm LED flashes

ADVANCED PROGRAMMING

4. Once you have filled out the table, it should look something like this.

You may refer to e ach column representing the zone dependent feature, to program
each zone with the selected feature. For example, Auto Mute feature is only enabled
for zone 3, when you are in the auto mute programming, you should enable this
feature for zone 3 only, the rest of the zones should have this feature disabled.
Repeat this step for all 4 zone dependent features during programming.

5. You may now follow the procedure below "Learn Sensor Continue" to program

the sensor(s) to the desired zone(s).

Learn Sensors - Continue

1

2

3

4

[PROG]
[MPIN]

Enter Program-
ming mode

Enter master
password to
programming mode

3 beeps for valid
password. 1 long beep
for invalid password.

[3]

Select learn
sensor
programming

[0] to [9]

After you have
selected the zone, that
zone LED will be on.

Trigger sensor

After [3] is entered, some
zone LEDs will flash
once, or twice, some will
be off. The zone LEDs
represent whether that
zone is already occupied
by another sensor. **

Select sensor
location

Refer to the diagram
below to select the
sensor location,
which includes the
zone and sensor
number.

Once the sensor is
activated, the signal
w ill be transmitted
to the Control Panel
which will be stored.

You will hear [Zone X
Sensor Y Accepted],
where X and Y are the
zone and sensor numbers
you have selected.

Activate the
sensor you
would like to
program to
this zone.

Basement Water

Front Window

Front Door

SENSOR 1

SENSOR 2

Location

Location

ZONE DEPENDENT FEATURES

Beep / Alarm

Auto Mute

Event Trigger

Alert

Kitchen Motion

Back Door

Basement Motion

Backyard Motion

Table C

zone 1

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 2

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 3

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 4

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 5

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

SENSOR 1

SENSOR 2

Location

Location

ZONE DEPENDENT FEATURES

Beep / Alarm

Auto Mute

Event Trigger

Alert

zone 1

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 2

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 3

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 4

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

zone 5

Beep / Alarm

Y / N

Disabled / On / Off

Y / N

Step

Keys

Function

Description

Note

35

Advertising