3. Transportation and Environment

3.1 Shipping condition

(1) All SANDEX products are thoroughly inspected after the final assembly. Only those

products that pass this inspection are shipped.

(2) Before shipped, each SANDEX unit is filled with lubrication oil in accordance to the

customer’s operating speed and environment.

(3) A rust preventative solution is applied to the input /output shafts, key, and mounting

surface. Vinyl tape is also used extensively to protect your SANDEX unit from
scratches while transporting.

Remove the rust preventative solution with a light oil or thinner. Be careful not to let the
light oil or thinner contact the oil seal. Never use thinner on or near the plastic sight gauge.
This may cause severe clouding of the material.

3.2 Temperatures

(1) For use between -20 to 0 degrees Celsius, (-4 to 32°F) use a lubricating oil with a lower

viscosity than the recommended oil. This is because the dynamic viscosity of the
lubricating oil rises in low temperatures and may not allow proper speed acceleration.

(2) For use between 40 to 70 degrees Celsius, (104 to 158°F) use lubricating oil with a

higher viscosity than the recommended oil. This is because the dynamic viscosity of the
lubricating oil lowers in higher temperatures and reduce the life of the equipment.

(3) For use between 70 to 100 degrees Celsius, (158 to 212°F) replace the oil seal and O-ring

with a heat resistant synthetic rubber.

3.3 Moisture

Rust may occur in storage or if the main machine is washed with water. Water does not
have to come directly into contact with the unit to cause rust. Moisture, condensation, and
other sources of humidity can also cause rust.

To use under these conditions, the mounting surfaces and shafts of the unit must be
painted, or otherwise rust proofed. Applying mineral oil or grease to the mounting surfaces
has a rust preventative effect and should always be practiced.

In addition, if the unit is directly subject to water, the sealing devices on the input and
output must be changed to a waterproof construction.

3.4 Dust

SANDEX units are generally built resistant to dust. This is because the roller gear cam
mechanism is enclosed within its own housing, and then sealed off at the input and output
with an oil seal. However, depending on the amount of dust or other foreign particles, the

Advertising