Codeexample58 failed path marked unusable, To isolate the a4 or b4 fc link, Quiesce the i/o on the a4 or b4 fc link path – Sun Microsystems 6900 User Manual

Page 84: Break the connection by uncabling the link, Sun proprietary/confidential: internal use only

Advertising
background image

64

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

CODE EXAMPLE 5-8

Failed Path Marked Unusable

FRU Tests Available for the A4 or B4 FC Link
Segment

■

The

switchtest

can only be run from the Storage Service Processor.

■

The

linktest

can isolate the switch and the GBIC on the switch. It cannot

isolate the cable or the Sun StorEdge T3+ array controller.

▼

To Isolate the A4 or B4 FC Link

To isolate the A4 or B4 link, which is the FC link from the switch to the Sun StorEdge
T3+ array, follow these steps.

1. Quiesce the I/O on the A4 or B4 FC link path.

2. Run

linktest

(1M) from the Storage Automated Diagnostic Environment GUI to

isolate suspected failing components.

Alternatively, follow these steps:

1. Quiesce the I/O on the A4 or B4 FC link path.

2. Run

switchtest

(1M) to test the entire link (re-create the problem).

3. Break the connection by uncabling the link.

4. Insert the loopback connector in to the switch port.

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

ac0:bank0 memory connected configured ok

ac0:bank1

memory

empty

unconfigured unknown

c1

scsi-bus

connected

configured

unknown

c16

scsi-bus

connected

unconfigured unknown

c18

scsi-bus

connected

unconfigured unknown

c19

scsi-bus

connected

unconfigured unknown

c1::dsk/c1t6d0

CD-ROM

connected

configured

unknown

c20

fc-private

connected

unconfigured unknown

c21

fc-fabric

connected

configured

unknown

c21::50020f2300006355

disk

connected

configured

unusable

Advertising
This manual is related to the following products: