Quiescing the i/o on the a3 or b3 link, Determine the path you want to disable, Disable the path by typing the following – Sun Microsystems 6900 User Manual

Page 79: Verify that the path is disabled, Suspending the i/o on the a3 to b3 link, Sun proprietary/confidential: internal use only

Advertising
background image

Chapter 5

Troubleshooting the Fibre Channel (FC) Links

59

Sun Proprietary/Confidential: Internal Use Only

Quiescing the I/O on the A3 or B3 Link

1. Determine the path you want to disable.

2. Disable the path by typing the following:

3. Verify that the path is disabled:

Steps 1 and 2 halt I/O only up to the A3 to B3 link. I/O continues to move over the
T1 and T2 paths, as well as the A4 to B4 links to the Sun StorEdge T3+ array.

Suspending the I/O on the A3 to B3 Link

Use one of the following methods to suspend I/O while the failover occurs:

■

Stop all customer applications that are accessing the Sun StorEdge T3+ array.

■

Manually pull the link from the Sun StorEdge T3+ array to the switch and wait
for a Sun StorEdge T3+ array LUN failover.

■

After the failover occurs, replace the cable and proceed with testing and FRU
isolation.

■

After testing is complete and any FRU replacement is finished, return the
controller state back to the default by using the virtualization engine failback
command.

Caution –

This action will cause SCSI errors on the data host and a brief suspension

of I/O while the failover occurs.

# /usr/bin/vxdmpadm disable ctlr=<c

n

>

# /usr/bin/vxdmpadm listctlr all