Southbend EVS Tool Room lathe w/DRO SB1059F User Manual

Page 33

Advertising
background image

For Machines Mfg. Since 3/11

EVS Toolroom Lathe w/DRO

-31-

P R E P A R A T I O N

Electrocution could occur if you attempt this
procedure with the power wires connected to
the power source. The incoming power wires
must be disconnected from power before
performing this procedure.

L3

L2

L1

To Power

Supply

Hot

MASTER

POWER SWITCH

Hot

Hot

Ground

Figure 22. Power connection at master power switch.

4.

Make sure the wires have enough slack so

that they do not bind at the terminals.

5.

Close and lock the main electrical box door.

3.

Connect the incoming hot wires to the

upper master power switch terminals and
the ground wire to the ground terminal, as
illustrated in Figure 22.

Connecting Power

1.

Make sure the master power switch is

turned to the OFF position, then open the
electrical cabinet door.

2.

Refer

to

Figure 21 to identify the master

power switch and the hole at the bottom left
of the electrical cabinet for the incoming
power.

Figure 21. Electrical cabinet.

Incoming Power

Master

Power

Switch

To avoid unexpected start-up of lathe
components, keep the master power switch
turned OFF until instructed otherwise in the
following test run.

Advertising