12-10. The Main Alarms of Power Supply Troubles

Cause

Remote controller display

Outdoor protection

Power supply voltage is abnormal.

P2

(More than 260 V or less than 160 V between L and N phase)

Negative phase or defective phase

P5

Compressor contactor (Mg SW) is chattering.

H18

12-9. The Main Alarms of Unit Troubles

Trouble detected

Remote controller display

Indoor protection

Fan motor protection thermostat

P1

Outdoor protection

Fan motor protection thermostat

P2

Compressor protection thermostat

Abnormal discharge temp.

P3

High pressure switch

P4

Indoor protection

Float switch

P10

Indoor sensor

Open/or damaged

F1-F3

Outdoor sensor

Open/or damaged

F4-F9

Compressor

Compressor motor is overloaded.

H1

protection

Compressor motor is locked.

H2

Compressor current detection circuit is abnormal.

H3

Low pressure protector is activated.

H6

* Ref: Alarm “P9” is not generated if the remote controller is set at test run.

12-8. The Main Alarms of Mis-wiring & Mis-setting

Remote
controller
display

Nothing
displayed

• In case of individual remote control

• Remote controller not properly connected.
• Power supply not ON.

• Remote controller not properly connected.

• Wiring connection fault of

indoor/outdoor units

• Power supply of outdoor unit not ON.

• Combination of indoor/outdoor units is wrong.

* Power supply of some indoor unit is not ON.

•Improper wiring connections of ceiling panel

E1

E4

P9

(*)

E9

• 2 main remote controllers set.

E6

In case of group control In case of multiple remote control

• Wiring connection fault of some indoor/outdoor units

inside the group

Cause