Introduction


The ERTEC 200 is intended for the implementation of PROFINET devices with RT and IRT functionality. With its
integrated ARM946 processor and 2-port Ethernet switch with integrated PHYs and the option to connect an
external host processor system to a local bus interface, it meets all the requirements for implementing PROFINET
devices with integrated switch functionality.

1.1 Applications of the ERTEC 200

ƒ

Interface connection for high-precision drive control, including for PC-based systems

ƒ

Distributed I/O with real-time Ethernet interfacing

ƒ

PROFINET RT and IRT functionality

1.2 Features of the ERTEC 200

The ERTEC 200 is a high-performance Ethernet controller with the following integrated function groups:

•

High-performance ARM 946 processor with D-cache, I-cache, D-TCM memory

•

Multilayer AHB bus master/slave with AHB arbiter

•

IRT switch with 64-Kbyte communication RAM

•

2 Ethernet channels with integrated PHYs

•

Local Bus Unit (LBU) for connecting an external host processor (with boot capability)

• SDRAM

controller

• SRAM

controller

•

DMA controller, 1-channel

•

45 IO, with assignable parameters

•

UART (with boot capability)

•

SPI (with boot capability)

• 3

timers

• F-timer

• Watchdog

•

IRQ and FIQ interrupt controller

•

PLL with clock generator

•

8 Kbytes of BOOT ROM

•

304-pin FBGA housing

•

Different test functions

•

JTAG debug and trace interface


Copyright © Siemens AG 2007. All rights reserved.