Multiple pvcs mode – Siemens ADSL 500 User Manual

Page 30

Advertising
background image

SANTIS ADSL 50/500 User Manual

26

Multiple PVCs Mode

RADIUS

Server

Public IP(s)
Pre-assigned by ISPs

PC(s)

Service

Aggregator

STM-1

DSLAM

ADSL

Router

Loop

ISP

b

Hub

ISP

a

(PPPoE)
PVC2

PVC1
(IPoA)

PVC2b

PVC1a

128.12.0.0

140.196.0.0

Description:
As this ADSL Router supports multiple PVCs in the ADSL loop, you are allowed to configure several logical
channels in one physical loop. You can use mixed encapsulation types by applying them to different PVCs. When the
system starts up, it will connect to CO site through the PVCs according to the sequence they are created. Therefore
the default route will be the last PVC you created. You can also modify the default route manually from the IPRoute
page.

The traffic from CPE side will be sent to different PVCs according to the routing rules.

Configuration:
1.

Start up your browser and type 192.168.1.1 as the address to enter this ADSL web-based manager.

2.

Create the first PVC (e.g. PVC1) using the RFC1483 data mode.
Refer to the section of “Router Mode” for details.

3.

Create the second PVC (e.g.PVC2) using the PPPoE data mode. Refer to the section of

“PPPoE + NAT

Mode” for details.

4.

Save the configuration by execute System >Save and System >Restart to restart your router for initiating these
settings.