Auxiliary Circuit Breaker

Auxiliary circuit breaker should be installed near outdoor unit so that each

access is possible.
Main/outdoor power supply cable are connected to upper/lower terminal of
auxiliary circuit breaker.

It is necessary that the conduit kit for power supply to the outdoor unit be

installed between auxiliary power s/w and the outdoor unit.
(the conduit kit is optional)

Electrical Work

Outdoor

unit

Distribution
board

Conduit kit

Auxiliary

power

s/w

1 The supply voltage must be the same as the rated voltage of the air conditioner.

2 Prepare the power souce for exclusive use with the air conditioner.

3 Use 20 amperes time delay fuse or circuit breaker.

When using the special NFB, use the NFB to bear the capacity of the
air conditioner.

Otherwise, the shot circuit in the NFB may be occur.

Model

Power supply

Main power supply cable

Assembly cable

Operating current

Power consumption

UM18A1C2

AWG14

AWG17

8.0

1720

UM26A1C2

AWG14

AWG17

11.8

2580

UM27A1C3

AWG14

AWG17

12.2

2650

208-230V~, 60Hz Single phase