Sanyo 09KS51 User Manual

Submittal sheet, System, 09ks51

Advertising
background image

SUBMITTAL SHEET

SYSTEM

INDOOR/OUTDOOR

09KS51

KS0951/C0951

WALL MOUNT AIR CONDITIONER

GENERAL DATA (AT 115V)

POWER

V/PH/HZ

115/1/60

Circuit Ampacity, Min. (A)

15

Fuse size, Max.

(A)

15

COMPRESSOR

Rotary-Hermetic

No. used

1

R.L. Amps - L.R. Amps (A)

7.7-49

Crankcase Heater

OUTDOOR FAN - TYPE

Propeller

Dia. (in.) - No. used

16-17/32 - 1

Type Drive - No. speeds

Direct - 1

No. Poles - RPM (High)

6 - 600

No. Motors - W

1 - 21.6

CFM (High)

1020

F.L. Amps. (A)

0.7

OUTDOOR COIL - TYPE

Aluminum Fin & Copper Pipe

Fin Type - Pipe Type

Slit Plate - Inner Flat

Rows - F.P.I.

1 - 18

Face Area (sq.ft.)

4.2

Tube Size (in.)

3/8

INDOOR FAN - TYPE

Cross-flow

Dia. & Length (in.) - No. used

3-3/4 & 24-9/32-1

No. speeds

3 & Auto

No. Poles -RPM (High)

4-1,200

No. Motors - W

1 - 18.2

CFM (HI/MED/LOW)

270/240/220

F.L. Amps (A)

0.4

INDOOR COIL - TYPE

Alminum Fin & Copper Pipe

Fin Type - Pipe type

Slit Plate - Inner Flat

Rows - F.P.I.

2 - 18

Face Area (sq. ft.)

1.4

Tube Size (mm)

7

Drain Connection Size (in.)

23/32

REFRIGERANT

R22

Lbs. - R22 (O.D. Unit)

1.28

Control

Capillary Tube

Connection

Flare

Line Length, Max (ft.)

50

Lift difference, Max (ft.)

23

Line Size - in. O.D. Discharge 1/4
Line Size - in. O.D. Suction

3/8

DIMENSIONS (in.)

H

x

W

x

D

Indoor Unit

-Uncrated 10-5/8

x 31-11/16 x 6-31/32

-Crated

9-13/16 x 33-21/32 x 13-5/16

Outdoor Unit -Uncrated 21-1/4

x 31-1/2

x 11-13/32

-Crated

23-31/32 x 38-5/8

x 16-3/16

WEIGHT

INDOOR OUTDOOR

Net

(lbs.)

17.6

66.1

Shipping (lbs.)

22.0

75.0


Shipping Volume(cu.ft.)

2.51

8.67

SS09KS51-2

PERFORMANCE DATA @ ARI STANDARD CONDITIONS (115V)

COOLING
Total Capacity

(BTU/H)

9,000

Sensible Capacity (BTU/H)

6,420

Latent Capacity

(BTU/H)

2,580

SEER

10.0

Dehumidification

(Pints/H)

2.0

Amps

(A)

8.8

Power Inputs

(W)

900

Outdoor Sound Rating (bels)

7.0

FEATURE
Controls

Microprocessor

Remote Controller

LCD Wireless type

Temperature Control

IC Thermostat

Timer

ON/OFF, ProgramTimer

Night Setback

Built-In

Air Louver

(Horizontal)

Manual

(Vertical)

Auto

Power Failure Automatic Restart

Built-In

Self Diagnosis

N/A

OPTION
Refrigerant Line Set

AP0905BH (15 ft)
AP0907BH (20 ft)

AP0910BH (30 ft)

Air Clean-Filter

STK-ARF4B

Fresh Air Intake

N/A

Central Remote ON-OFF Control

Available

Airduct Extension

N/A

Indoor Frame Extension

N/A

Condensate Drain Pump

Optional

Non-Removable Remo-con Bracket

Optional

OPERATING RANGE
Cooling

Indoor Air

Outdoor Air

Intake Temp.

Intake Temp.

Maximum 95 F DB/71 F WB

115 F DB

Minimum

67 F DB/57 F WB

67 F DB

CERTIFICATION

09KS51

AIRCONDITIONING PRODUCTS

Advertising