SITE PREPARATION

Electrical

Installation must comply with all applicable electrical codes.

The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.

ELECTRICAL REQUIREMENTS

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

CAUTION

The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.

WARNING

Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.

FRONT VIEW

75

1

/

2

"

(1918)

FROM

FLOOR

7"

(178)

E

6"

(152)


Electrical supply location.

Dual Installation

If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 2"

(51)

filler strip is recommended between units.

Dual installations without a filler strip can only be accom-
plished using two units with opposite hinges. Refer to the
illustrations below.

Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the find a
showroom section of our website, subzero.com. For ques-
tions regarding the installation, call Sub-Zero customer care
at 800-222-7820.