Power strip control, Instruction manual – StarTech.com CONYX ECS0016 User Manual

Page 122

Advertising
background image

Instruction Manual

115

To set the Username field (SNMP version 3 only):
config set config.system.snmp.username2=yourusername ..
(replacing yourusername with the username config.system.snmp.
username2 (3 only))
To set the Engine ID field (SNMP version 3 only):
config set config.system.snmp.password2=yourpassword ..
(replacing yourpassword with the password)

Once the fields are set, apply the configuration with the following com-
mand:
config run snmp

You can add a third or more SNMP servers by incrementing the “2” in
the above commands, e.g. config.system.snmp.protocol3, config.system.
snmp.address3, etc.

nfig instead of /etc/ssh_config

/etc/config/users/<username>/.ssh/ instead of /
home/<username>/.ssh/

Power Strip Control

The console server supports a growing list of remote power-control
devices (RPCs) which can be configured using the Management Console
as described in Chapter 8. These RPCs are controlled using the open
source PowerMan tools and with the pmpower utility.
PowerMan
PowerMan provides power management in a data center or compute
cluster environment. It performs operations such as power on, power
off, and power cycle via remote power controller (RPC) devices. Target
hostnames are mapped to plugs on RPC devices in powerman.conf