Form No. 702703 Rev. E August, 2006

19

Owner’s Manual - Oxygen Therapy Door

Procedures

Nebulizer Assembly,

Complete

This is the complete nebulizer assembly including the bottle, cap,
regulator, extension, cotter pin, hose barb fitting and oxygen supply
hose (Figure 18).

Tool Required
„

Needle-nose pliers

P/N 212126

Procedure
1.

On the nebulizer extension, use a needle-nose pliers to
squeeze the two ends of the cotter pin together, then
remove the pin from the extension (Figure 19).

2.

Open the oxygen therapy door.

3.

Place the nebulizer in the ice tray with the extension
through the opening in the door (Figures 19 and 20).

4.

Inside the door, replace the cotter pin into the extension
to hold the nebulizer in place and spread the two cotter
pin ends apart to keep the pin from falling out.

Figure 18. Nebulizer Assembly, Complete

Bottle

Cap

Regulator

Hose Barb

Fitting

Cotter Pin

Extension

Oxygen

Supply Hose