ALARM IN SET : Select the alarm sensor operation between <NO>, <NC> and 
<OFF>.
ALARM OUT SET : Set the alarm out port matched to the alarm input port.
AUTO SET : Sets the pattern and scan 
action for the corresponding alarm 
input. When the alarm is generated, the 
camera moves to the preset position 
coupled to the corresponding alarm. 
Presets 1 ~ 8 are coupled with alarms 
1 ~ 8 inputs respectively, and the preset 
9 is coupled to the motion detection. 
The camera stops and remains in the 
corresponding preset position for the 
defined <DWELL TImE>, and performs 
pattern or scan action defined by the <AUTO SET>. Setting to <OFF> will 
discard with the pattern or scan action after moving to the preset position. 
- PATTERN 1 ~ 3 : Defined pattern action 
- HALF1 : Patterns 1 and 2 in serial action 
- HALF2 : Patterns 2 and 3 in serial action 
- WHOLE : Patterns 1, 2 and 3 in serial action 
- SCAN 1 ~ 4 : Predefined SCAN action
The <
ALARM1> is used as external switching signal if the <DAY/NIGHT> is set to
<
EXT>.
AUX OUT CONTROL : Sets whether to 
sustain the alarm output despite of the 
alarm generation or to output alarm out 
signal while the coupled alarm is alive. 
When selected <OFF>, outputs alarm 
only if the alarm is generated. When 
selected <ON>, it always outputs 
alarm out signal despite of the alarm 
generation.
M
AUX OUT CONTROL
OUT1
OFF
OUT2
OFF
OUT3
OFF
AUTO SET
ALARM1
OFF
ALARM2
OFF
ALARM3
OFF
ALARM4
OFF
ALARM5
OFF
ALARM6
OFF
ALARM7
OFF
ALARM8
OFF
MOTION
OFF