Auxiliary circuit breaker electrical work – Samsung AQ30C1(2)BC User Manual

Page 40

Advertising
background image

E-

40

I

NSTALLING THE

O

UTDOOR

U

NIT

Auxiliary Circuit Breaker

Electrical Work

1

The supply voltage must be the same as the rated voltage of the
air conditioner.

2

Prepare the power souce for exclusive use with the air conditioner.

3

Use 15 amperes time delay fuse or circuit breaker.

When using the special NFB, use the NFB to bear the capacity of the
air conditioner.

Otherwise, the shot circuit in the NFB may occur.

Auxiliary circuit breaker should be installed near outdoor unit so

that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.

It is necessary that the conduit kit for power supply to the outdoor

unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)

MODEL

AQ30

✴✴

BC

Power cable

Assembly cable

Operating current(C/H)

Starting Current

Power consumption (C/H)

Power supply

208-230V~/60Hz

Single phase

3G AWG 12

5G AWG 14 + 2G AWG 18

80A

14A / 14A

3100W / 3100W

Outdoor unit

Distribution

board

Auxiliary

power s/w

Advertising