7. TECHNICAL DESCRIPTION

7.1. TECHNICAL SPECIFICATION

Dimensions and weight:

•

Width: 48.9 mm [1.92 in]

•

Height: 54.8 mm [2.16 in]

•

Thickness: 15.8 mm [0.62 in]

•

Weight: 50.3 g [1.78 oz]

Depth Gauge:

•

Temperature compensated pressure sensor.

•

Salt water calibrated, in fresh water the readings are about 3% smaller
(calibrated complying with prEN 13319).

• Maximum depth of operation: 80 m [262 ft] (complying with prEN

13319).

•

Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at 20°C
[68°F] (complying with prEN 13319).

•

Depth display range: 0 … 99.9 m [300 ft].

•

Resolution: 0.1 m [1 ft].

Temperature display:

•

Resolution: 1ºC [1.5ºF]

•

Display range: - 20 ... +50ºC [- 4 ... +122ºF]

•

Accuracy: ± 2ºC [± 3.6ºF] within 20 minutes of temperature change