4-3.DC mode
1. Selection of bar length
・Select the length applicable to work size base on static charge elimination area and static charge
elimination characteristics.
2. Installation of body
・Keep the distance between the ionizer and charged objects within 50 to 2000mm. Although the ionizer
can be mounted outside of this range, it may not operate properly depending on the operating conditions.
Therefore, be sure to check if the ionizer will operate properly.
3. Installation of the sensor
・[Plus ion discharge] or [minus ion discharge] can be selected.
Ion polarity
Switch setting
Plus ion discharge
8
Minus ion discharge
9
4. Wiring of the power supply cable
・Connect dedicated power supply cables.
Connection with the power supply for ionizer operation
Symbol Cable
color
Cable name
Connection
Description
DC1(+)
Brown Power
supply
DC24V
○
DC1(-)
Blue Power
supply
GND[FG]
○
Power supply cable for
ionizer operation
OUT4 Dark
Green
Sensor monitor output
-
-
※ Be sure to ground DC1(-)[Blue].(Resistance between the lead wire and the earth ground should be 100Ωor less.)
If not, it may break the ionizer.
Connection with the power supply for I/O signal
Symbol Cable
color
Cable name
Connection
Description
DC2(+)
Red Power
supply
DC24V
○
DC2(-)
Black Power
supply
GND
○
Power supply cable for I/O signal
IN1 Light
Green
Discharge-stop signal
○
Signal for starting/ stopping the discharge
(NPN spec)Operation will begin when it is connected
with DC2(-)[Black].
(PNP spec)Operation will begin when it is connected
with DC2(+)[Red].
IN2 Gray
Maintenance
start-up
signal
-
-
-
White
-
-
-
-
Orange
-
-
-
OUT1 Pink
Completion signal for
static charge elimination
-
-
OUT2 Yellow
Maintenance
output
signal
-
-
OUT3 Purple
Signal for failure
△
Outputs in case of abnormal high voltage and sensor
and/or CPU failure.
(B contact output)
○ : Wires that are minimum required to operate the ionizer.
△ : Wires that are required to use the functions.
- : Wires that are not necessary with the sensing DC mode. These wires should not be short-circuited with other
cables.
5. Air piping
・When the piping is only connected to one port, the other unused port should be plugged with the M-5P
that is packaged together with the ionizer.
Brown
Blue
Ground
DC Power supply