Galaxy 5000RS Plus - Page 21

FM module must be connected before completing this step.
FM Remote Learn. Learns the optional 2-way FM transmitter. Press Button 2 on the 1-way remote to

enter FM Transmitter learn mode, then press transmitter Button 1 on each FM remote (max 2).
*Requires the optional ScyNet FM LCD Pager Module.

23. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 relay output:

Ignition 2, Accessory 2, or Starter 2.

24. Horn Output. When set for Horn Output the horn wire will pulse when the alarm is triggered. When

Ignition 3 Output is selected, the output will activate during remote start to trigger a relay for Ignition 3.

25. Turbo Timer. When enabled, if the emergency brake has been applied Ignition power will be kept On

for a predetermined time (2min. Factory Default) from the application of the emergency brake.

Real-time Sensor Adjustment Mode

This mode allows active testing and adjustment of the shock sensor without arming the alarm.
To enter Sensor Adjustment mode:

1. Turn on the ignition.
2. Within 5 seconds, press the Shift Button 3 times followed by Button 3.

· The siren will chirp 4 times, indicating that the sensors are ready to be tested.

3. Turn off the ignition and test the sensitivity. The siren will chirp each time a sensor is disturbed.

· The siren will chirp 1 time for Shock Sensor trigger.
· The siren will chirp 2 times for Warn Away trigger.
· The siren will chirp 3 times for Optional Sensor trigger.

4. When the sensors are properly adjusted, turn on and off the ignition to exit adjust mode.